e-ISSN: 2717-7149
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Retina Arter Tıkanıklıkları ve Tedavisi...
Santral Retinal Ven Tıkanıklığı Güncel Tedavisi...
Central Retinal Artery Occlusion As the Cause of Unilateral Concentric Narrowing of Visual Field and Presence of Cilioretinal Artery...
Bilateral Optic Disc Drusen
Vascular Endothelial Growth Factor and Anti VEGF Agents...
Central Retinal Artery Occlusion As the Cause of Unilateral Concentric Narrowing of Visual Field and Presence of Cilioretinal Artery...
Retina Arter Tıkanıklıkları ve Tedavisi...
Morning Glory Syndrome Associated with Retinochoroidal Coloboma...
Santral Retinal Ven Tıkanıklığı Güncel Tedavisi...
Bilateral Optic Disc Drusen
PureSee Kesintisiz Yüksek Kalitede Görüş
Retina-Vitreous 2013 , Vol 21 , Num 2
Turkish Abstract Abstract Article PDF Similar Articles Mail to Author
Passive Silicone Oil Removal with 23-Gauge Transconjunctival System
Şengül ÖZDEK1, Berrak ŞEKERYAPAN2, Fulya YAYLACIOĞLU3
1M.D. Professor, Gazi University Faculty of Medicine, Department of Ophthalmology, Ankara/TURKEY
2M.D. Asistant Professor, Recep Tayyip Erdogan University Faculty of Medicine, Department of Ophthalmology, Rize/TURKEY
3M.DAsistant, Gazi University Faculty of Medicine, Department of Ophthalmology, Ankara/TURKEY
Purpose: To introduce the results of passive removal of 1000 centistokes (cs) silicone oil with 23 gauge transconjunctival system.

Materials and Methods: Ninety-one eyes of 91 patients were studied retrospectively. 23-gauge trocar cannulas were entered from the pars plana in two steps and waited for removal of silicone oil from the trocar cannulas passively. The reason for the primary surgery, preoperative and postoperative visual acuities and intraocular pressures, duration of silicone oil removal, need for peroperative suture, additional surgical procedures, complications and postoperative follow-up time were recorded.

Results: Mean follow-up time was 15.9±6.1 months. 37 eyes (40.6%) were underwent additional operations as phacoemulsification, epiretinal membrane peeling and/or endolaser during surgery. Mean duration of silicone oil removal was 7.1±0.5 minutes. Mean intraocular pressure decreased significantly at all visits postoperatively; and it was measured as 10.9±2.2 mmHg at the first day, 15.9±5.4 mmHg at the first month and 14.9±2.2 mmHg at the 6th month. 26 eyes (28.5%) peroperatively needed at least one suture. Postoperatively, visual acuity increased in 35 eyes (38.4%). Only in one eye postoperative serious hypotonia (intraocular pressure<5 mmHg) was recorded. 6 eyes (6.6%) were reoperated due to the redetachment of the retina after silicone oil removal.

Conclusion: Removal of 1000 cs silicone oil with 23 gauge transconjunctival system is effective, fast, safe and comfortable. Postoperative complications are rare. Keywords : 23 gauge, transconjunctival, passive silicone oil removal

PureSee Kesintisiz Yüksek Kalitede Görüş
Home
About The Journal
Editorial Board
Instructions for Authors
Contact