e-ISSN: 2717-7149
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Retina Arter Tıkanıklıkları ve Tedavisi...
Santral Retinal Ven Tıkanıklığı Güncel Tedavisi...
Central Retinal Artery Occlusion As the Cause of Unilateral Concentric Narrowing of Visual Field and Presence of Cilioretinal Artery...
Bilateral Optic Disc Drusen
Vascular Endothelial Growth Factor and Anti VEGF Agents...
Central Retinal Artery Occlusion As the Cause of Unilateral Concentric Narrowing of Visual Field and Presence of Cilioretinal Artery...
Retina Arter Tıkanıklıkları ve Tedavisi...
Morning Glory Syndrome Associated with Retinochoroidal Coloboma...
Santral Retinal Ven Tıkanıklığı Güncel Tedavisi...
Bilateral Optic Disc Drusen
PureSee Kesintisiz Yüksek Kalitede Görüş
Retina-Vitreous 2015 , Vol 23 , Num 4
Turkish Abstract Abstract Article PDF Similar Articles Mail to Author
Comparison of Central Retinal Thickness Measurements with Optical Low Coherence Reflectometry and Spectral Domain Optical Coherence Tomography in Normal Subjects
Handan BARDAK1, Yavuz BARDAK2
1M.D. Special Kariyer Eye Hospital, Isparta/TURKEY
2M.D. Professor, Special Kariyer Eye Hospital, Isparta/TURKEY
Purpose: To compare measurements of central retinal thickness (RT) obtained with optical low coherence reflectometry (OLCR) and spectral domain optical coherence tomography (SD-OCT) in healthy subjects.

Methods: Thirty-nine eyes of 39 subjects (51.3% male, 48.7% female) without any ocular and systemic disease had central RT measurements. Measurements with OLCR and SD-OCT were repeated 3 times.

Results: The mean RT measurements; with OLCR was 195.02±11.78 (173.3-219.6) μm, and with SD-OCT was 222.96±11.34 (205-255) μm. The mean difference between OLCR and SD-OCT RT measurements was 27.94±8.68 μm (p=0.001; p<0.01). There were, high positive correlation (r=0.719; p=0,001; p<0.01), high agreements (95% LoA lower limit 10.91 upper limit 44.96) and good correlation (r>0.90, p<0.05) between OLCR and SD-OCT RT measurements.

Conclusion: In healthy subjects central RT measurements; derived from OLCR and SD-OCT, exhibit a high positive relation, strong correlation and good agreement. Keywords : Central retinal thickness, optical low coherence reflectometry, spectral domain optical coherence tomography