e-ISSN: 2717-7149
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Retina Arter Tıkanıklıkları ve Tedavisi...
Santral Retinal Ven Tıkanıklığı Güncel Tedavisi...
Central Retinal Artery Occlusion As the Cause of Unilateral Concentric Narrowing of Visual Field and Presence of Cilioretinal Artery...
Bilateral Optic Disc Drusen
Vascular Endothelial Growth Factor and Anti VEGF Agents...
Central Retinal Artery Occlusion As the Cause of Unilateral Concentric Narrowing of Visual Field and Presence of Cilioretinal Artery...
Retina Arter Tıkanıklıkları ve Tedavisi...
Morning Glory Syndrome Associated with Retinochoroidal Coloboma...
Santral Retinal Ven Tıkanıklığı Güncel Tedavisi...
Bilateral Optic Disc Drusen
PureSee Kesintisiz Yüksek Kalitede Görüş
Retina-Vitreous 2017 , Vol 26 , Num 2
Turkish Abstract Abstract Article PDF Similar Articles Mail to Author
Intraocular Pressure Changes after Single Dexamethasone Implant Injection: A real life clinical study, review of 1110 cases
İhsan YILMAZ1, Başak SARAÇOĞLU2, Sibel AHMET2, Ökkeş BAZ1, Abdullah ÖZKAYA3, Muhittin TAŞKAPILI3
1Uz. Dr., Beyoğlu Eye Training and Research Hospital, Ophthalmology, Istanbul - TÜRKİYE
2Asist. Dr., Beyoğlu Eye Training and Research Hospital, Ophthalmology, Istanbul - TÜRKİYE
3Doç. Dr., Beyoğlu Eye Training and Research Hospital, Ophthalmology, Istanbul - TÜRKİYE
Purpose: To evaluate intraocular pressure (IOP) changes after single administration of dexamethasone implant (DI).

Methods: 1110 eyes of 1110 patients were included in this retrospective study. 726 eyes had DME, 262 eyes had macular edema secondary to branch retinal vein occlusion, and 122 eyes had macular edema secondary to central retinal vein occlusion. Data were collected at baseline, and each monthly visit. All adverse events during DI injection and during 6-month follow-up were recorded. IOP was measured at baseline and each visit.

Results: The mean ages was 61.6±8.5 year (range: 22-88 years). There was no signifi cant differences in mean IOP measurements among values taken prior to injection and during each monthly visit afterward (p>.050). 168 eyes had IOP values of more than 20 mmHg during the follow-up period in general. 98 eyes did not receive any treatment, 65 eyes were treated with topical drops. 5 eyes were treated with selective laser trabeculoplasty. No surgery was required for any patient. No systemic adverse event observed.

Conclusion: DI injection may not carry a big risk of IOP rising in fi rst 6 months. Also there may be no systemic adverse events associated with DI injection in fi rst 6 months. Keywords : corticosteroids, dexamethasone implant, diabetic macular edema, intravitreal injection, retinal vein occlusion

PureSee Kesintisiz Yüksek Kalitede Görüş
Home
About The Journal
Editorial Board
Instructions for Authors
Contact