e-ISSN: 2717-7149
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Retina Arter Tıkanıklıkları ve Tedavisi...
Santral Retinal Ven Tıkanıklığı Güncel Tedavisi...
Central Retinal Artery Occlusion As the Cause of Unilateral Concentric Narrowing of Visual Field and Presence of Cilioretinal Artery...
Bilateral Optic Disc Drusen
Vascular Endothelial Growth Factor and Anti VEGF Agents...
Central Retinal Artery Occlusion As the Cause of Unilateral Concentric Narrowing of Visual Field and Presence of Cilioretinal Artery...
Retina Arter Tıkanıklıkları ve Tedavisi...
Morning Glory Syndrome Associated with Retinochoroidal Coloboma...
Santral Retinal Ven Tıkanıklığı Güncel Tedavisi...
Bilateral Optic Disc Drusen
PureSee Kesintisiz Yüksek Kalitede Görüş
Retina-Vitreous 2007 , Vol 15 , Num 1
Turkish Abstract Abstract Article PDF Similar Articles Mail to Author
Short Posterior Ciliary Artery Blood Flow Parameters in Central Serous Chorioretinopathy
Nurettin DENİZ1, Mustafa KOÇ2, Ülkü ÇELİKER3
1Fırat Üniv. Tıp Fak. Göz. Hast. A.D., Elazığ, Arş. Gör. Dr.
2Fırat Üniv. Tıp Fak. Radyoloji A.D., Elazığ, Arş.Gör.Dr.
3Fırat Üniv. Tıp Fak.Göz. Hast. A.D., Elazığ, Prof. Dr.
Purpose: Evaluation of short posterior ciliary artery (PCA) blood flow in central serous chorioretinopathy (CSC) with color Doppler ultrasonography

Matherials and Methods: Between January 2005-February 2006, short posterior ciliary artery blood flow of 16 patient with acute CSC were examined by color Doppler ultrasonography and compared with 16 patients with no systemic or ocular disease. Peak systolic rate (PS), end diastolic rate (ED), resistivity index (RI), pulsatility index (PI) of all cases were evaluated.

Results: Mean PS of PCA of the patient group was 30.81±3.17, of the control group was 26.90±1.54 (p>0.05). Mean ED of PCA of the patient group was 10.75±0.87, and of the control group was 9.37±0.67 (p>0.05). Mean RI value of the patient group was 0.61±0.03, of the control group was 0.63±0.02 (p>0.05). Mean PI of PCA of the patient group was 1.31±0.06, and of the control group was 1.19±0.04 (p>0.05).

Conclusion: Statistically,there was no difference in mean blood flow parameters of PCA in CSC with color Doppler ultrasonography. Keywords : Acut CSC, color doppler ultrasonography, short posterior ciliary artery