e-ISSN: 2717-7149
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Retina Arter Tıkanıklıkları ve Tedavisi...
Santral Retinal Ven Tıkanıklığı Güncel Tedavisi...
Central Retinal Artery Occlusion As the Cause of Unilateral Concentric Narrowing of Visual Field and Presence of Cilioretinal Artery...
Bilateral Optic Disc Drusen
Vascular Endothelial Growth Factor and Anti VEGF Agents...
Central Retinal Artery Occlusion As the Cause of Unilateral Concentric Narrowing of Visual Field and Presence of Cilioretinal Artery...
Retina Arter Tıkanıklıkları ve Tedavisi...
Morning Glory Syndrome Associated with Retinochoroidal Coloboma...
Santral Retinal Ven Tıkanıklığı Güncel Tedavisi...
Bilateral Optic Disc Drusen
PureSee Kesintisiz Yüksek Kalitede Görüş
Retina-Vitreous 2007 , Vol 15 , Num 0
Turkish Abstract Abstract Article PDF Similar Articles Mail to Author
The Different Kinds of Perfluorocarbons, Advantages and Disadvantages
Hülya KOCAOĞLAN
Serbest Hekim, Ankara, Doç Dr. Perfluorocarbon liquids (PFCL) are fluorinated synthetic analogues of hydrocarbons containing carbon-fluorine bonds. PFCL’s are colorless, odorless and possess high density (1.6 to 2.1 specific gravitiy) and low viscosity (2 to 3 centistokes at 25oC). These liquids are all optically clear and have a refractive indexes slightly different from saline, allowing the use of conventional contact lenses without optic aberrations. The difference in refractive index also creates a visible interface between saline and PFCL. They have low surface tension this property decreases the likehood of subretinal migration of PFCL. The boiling point of PFCL is higher than water, allowing the application of endophotocoagulation. The most commonly used PFCLs are perfluoro-n-octane, perfluorodecaline and perfluoroperhydrophenanthrene. PFCLs compared of only carbon and fluorine atoms have greater biologic stability than those compounds containing nitrogen, oxygen and hydrogen. Their high specific gravity allow for stabilizing the retina during peeling and delamination of membranes as a third hand. Their significant tamponate force is approximately six times greater than that of fluorosilicone oil. PFCLs are safe for intraoperative use, they cannot be left in the vitreous cavity for extended periods because of ocular toxicity. Keywords : Perfluorocarbon liquids
PureSee Kesintisiz Yüksek Kalitede Görüş
Home
About The Journal
Editorial Board
Instructions for Authors
Contact