e-ISSN: 2717-7149
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Retina Arter Tıkanıklıkları ve Tedavisi...
Santral Retinal Ven Tıkanıklığı Güncel Tedavisi...
Central Retinal Artery Occlusion As the Cause of Unilateral Concentric Narrowing of Visual Field and Presence of Cilioretinal Artery...
Bilateral Optic Disc Drusen
Vascular Endothelial Growth Factor and Anti VEGF Agents...
Central Retinal Artery Occlusion As the Cause of Unilateral Concentric Narrowing of Visual Field and Presence of Cilioretinal Artery...
Retina Arter Tıkanıklıkları ve Tedavisi...
Morning Glory Syndrome Associated with Retinochoroidal Coloboma...
Santral Retinal Ven Tıkanıklığı Güncel Tedavisi...
Bilateral Optic Disc Drusen
PureSee Kesintisiz Yüksek Kalitede Görüş
Retina-Vitreous 2023 , Vol 32 , Num 1
Turkish Abstract Abstract Free Full Text English Similar Articles Mail to Author
Comparative Study of Retinal Detachment Surgery Using a Silicone Sponge with and without Tenon?s Capsule Covering
Lukpan Orazbekov1, Elmira Kanafyanova2, Kairat Ruslanuly2
1Kazakh Eye Research Institute, First Ophthalmology Department, Almaty, Kazakistan
2Kazakh Eye Research Institute, Postgraduate Education Department, Almaty, Kazakistan
DOI : 10.37845/ret.vit.2023.32.6 Purpose: To perform and compare the results of circumferential buckling using a silicone sponge with and without Tenon?s capsule covering.

Materials and Methods: We analyzed cases of silicon sponge rejection after 691 cases of circumferential buckling using a silicone sponge in retinal detachment from 2007 to 2020. Depending on whether a silicone sponge was covered with Tenon?s capsule, all cases were divided into two groups: Group A (covered) ? 349 cases; Group B (not covered) ? 342 cases. The follow-up period was up to 2 years.

Results: In Group A, where a silicone sponge was covered with Tenon?s capsule, the rate of silicon sponge rejection was 0.3% (1 case), while in Group B, where the operation was performed classically, the rate of silicon sponge rejection was 5.2% (18 cases) (p<0.01).

Conclusions: Our study shows the possibility of minimizing the silicon sponge rejection with a simple method: covering a silicone sponge with Tenon?s capsule. Keywords : scleral buckling, silicone sponge rejection, Tenon?s capsule, retinal detachment surgery